====== SCT013 (30A) ====== Open-Close Current Transformer Non-invasive AC Current Sensor Split Core Current Transformer {{:components:sct013.png?nolink&200|}} Retractable transformer SCT-013 Rated Input Current : 30A Features : Opening size: 13mm × 13mm, is fully compatible with similar foreign products ; non-linearity of ± 3% (10% ~ 120% of rated input current ) ; lead length 1.5 m , the standard three-pin plug Φ3.5 output ; current, voltage, two output forms ( built- shaped output voltage sampling resistor ) . Uses: Current measurement for AC motors, lighting equipment , air compressor , monitoring and protection. Core material : ferrite mechanical strength : opening and closing times of not less than 1000 times (20 °c test ) Safety indicators : Dielectric strength ( between housing and output ) 6000V AC / 1min retardant characteristics meet UL94-V0 Operating temperature : -25 ° C~ + 70 °C